4405HS4″ Sch 40 Radon / Vapor Floor Seal

Documentation

Testing & Compliance

SlabCollar is manufactured from a fully characterized EPDM compound and screened against international substance-restriction standards.

01

Material Performance

ASTM D2000 Line Call-out

M4CA510A25B35EA14F17

Service Temperature

−55 °C to +125 °C (−67 °F to +257 °F)

PropertyTest MethodConditionResultStatus
HardnessASTM D2240Shore A48 (spec 50 ±5)Pass
Tensile StrengthASTM D412Die C15.8 MPa (min 10)Pass
Elongation at BreakASTM D412Die C690% (min 300)Pass
Tear ResistanceASTM D624Die C43 kgf/cm (≈42 kN/m)Pass
Compression SetASTM D395Method B, 22 h @ 70 °C9%Pass
Compression SetASTM D395Method B, 22 h @ 100 °C13%Pass
Low-Temperature BrittlenessASTM D2137Method A, −55 °C × 3 minNo failurePass
Heat AgeingASTM D2000 A2570 h @ 125 °CHardness +3 pts, tensile −5%, elongation −16%Pass
Water ResistanceASTM D2000 EA1470 h @ 100 °CVolume change +3.6%Pass
Ozone ResistanceASTM D117150 pphm, 40 °C, 72 h, 20% elong.No crackingPass
Specific Gravity1.20 g/cm³Reported

Material performance data from the compound manufacturer’s test report.

02

Regulatory Compliance

Independently tested by SGS.

StandardScopeResultStatus
EU RoHS — (EU) 2015/863Pb, Hg, Cd, Cr⁶⁺, PBB, PBDE, DEHP, BBP, DBP, DIBPAll Not DetectedCompliant
EU REACH — SVHC Candidate List253 Substances of Very High ConcernAll ≤ 0.1% by weightCompliant
California Proposition 65Lead, cadmium, phthalatesAll Not DetectedCompliant

Testing performed on the EPDM compound used in SlabCollar 4405HS.

03

Performance Verified In-House

Tested by SlabCollar on production parts.

Pipe Support — over 200 lb

The internal support ledge catches the cut end of the pipe so it can't drop into the hole or pit. The seal happens on the smooth pipe wall about an inch above, so a rough field cut never affects it.

Result

Supports over 200 lb.

Airtight Seal

With the boot and pipe seated, the four sealing interfaces close the soil-gas path at the slab surface, the cored-hole wall, and the pipe.

Result

Airtight when properly installed.

04

Request Documentation

Full test reports and compliance documentation are available to specifiers, distributors, and mitigation professionals on request.

Request Documentation